- The OZ-0500AC is designed to assess the resistance of vulcanized and thermoplastic rubber to cracking under static or dynamic strain when exposed to an ozone environment.
- This ozone tester offers controllable ozone concentration and temperature conditions and allows operators to assess the resistance of rubber materials to ozone exposure efficiently for product performance evaluation.
-
Standards
- GB/T 7762-2014
- GB/T 13642-2015
- ASTM D 1149-18
- ISO 1431-1:2012
Principle
The ozone tester is specifically designed to assess the cracking resistance of vulcanized and thermoplastic rubber under static or dynamic strain in an ozone environment. It provides precise control over ozone level and temperature, enabling operators to replicate real-world conditions efficiently.
Wide applicability:
Well-suited for diverse industries such as aerospace, rubber, electronics, and industrial manufacturing.
Environmental simulation:
Capable of simulating various environmental conditions over ozone level and temperature, precisely replicating real-world conditions.
High efficiency solution:
Provides an efficient and reliable solution that enables manufacturers to speed up product performance evaluation and product design.
Standardized testing:
Delivers standardized test methods and comparable test results, enabling manufacturers to maintain product quality consistency.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Industrial-grade ozone analyzer
The advanced ozone analyzer delivers reliable, steady, and precise detection of ozone concentration.
Multiple grip options
Compatible with a variety of grips suitable for rubber specimens of different shapes and sizes.
Touchscreen interface
The intuitive and user-friendly touchscreen interface enables operators to easily complete parameters setup and conduct tests.
High precision control
Utilizing sophisticated control systems, the ozone tester precisely manages ozone concentration, temperature, and other test conditions, ensuring accurate and reliable test results.
Real-time data monitor
Provides valuable insights into the test process while ensuring that test conditions are maintained at optimal levels.
Long-term reliability
Built with a durable mechanical structure and sophisticated control systems, the ozone tester ensures long-term reliability and high efficiency.
-
左右滑動看表格
Temp. range Ambient temp. +10℃~80℃ Temp. accuracy ±0.5℃ Humidity range 50%RH to 80%RH
(Note 1: Correspond to temp. range between 23℃ and 40℃)
(Note 2: Humidity generation is offered as an optional feature)Humidity accuracy ±5%RH Ozone concentration range 20 pphm to 1000 pphm Ozone concentration accuracy <200pphm±4pphm
<500pphm±10pphm
<1000pphm±20pphmOzone fluctuation <±2pphm Interior dimensions (W×D×H) 50×50×60cm Ozone detection UV light absorption Ozone analyzer 465L ozone analyzer Power 1∮ AC 220V 50/60Hz 2.7kW (or specify)
*Product design and specifications are subject to change without notcie.
-
Details
Standards
- GB/T 7762-2014
- GB/T 13642-2015
- ASTM D 1149-18
- ISO 1431-1:2012
Principle
The ozone tester is specifically designed to assess the cracking resistance of vulcanized and thermoplastic rubber under static or dynamic strain in an ozone environment. It provides precise control over ozone level and temperature, enabling operators to replicate real-world conditions efficiently.
Wide applicability:
Well-suited for diverse industries such as aerospace, rubber, electronics, and industrial manufacturing.
Environmental simulation:
Capable of simulating various environmental conditions over ozone level and temperature, precisely replicating real-world conditions.
High efficiency solution:
Provides an efficient and reliable solution that enables manufacturers to speed up product performance evaluation and product design.
Standardized testing:
Delivers standardized test methods and comparable test results, enabling manufacturers to maintain product quality consistency.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Features
Industrial-grade ozone analyzer
The advanced ozone analyzer delivers reliable, steady, and precise detection of ozone concentration.
Multiple grip options
Compatible with a variety of grips suitable for rubber specimens of different shapes and sizes.
Touchscreen interface
The intuitive and user-friendly touchscreen interface enables operators to easily complete parameters setup and conduct tests.
High precision control
Utilizing sophisticated control systems, the ozone tester precisely manages ozone concentration, temperature, and other test conditions, ensuring accurate and reliable test results.
Real-time data monitor
Provides valuable insights into the test process while ensuring that test conditions are maintained at optimal levels.
Long-term reliability
Built with a durable mechanical structure and sophisticated control systems, the ozone tester ensures long-term reliability and high efficiency.
-
Specifications左右滑動看表格
Temp. range Ambient temp. +10℃~80℃ Temp. accuracy ±0.5℃ Humidity range 50%RH to 80%RH
(Note 1: Correspond to temp. range between 23℃ and 40℃)
(Note 2: Humidity generation is offered as an optional feature)Humidity accuracy ±5%RH Ozone concentration range 20 pphm to 1000 pphm Ozone concentration accuracy <200pphm±4pphm
<500pphm±10pphm
<1000pphm±20pphmOzone fluctuation <±2pphm Interior dimensions (W×D×H) 50×50×60cm Ozone detection UV light absorption Ozone analyzer 465L ozone analyzer Power 1∮ AC 220V 50/60Hz 2.7kW (or specify)
*Product design and specifications are subject to change without notcie.