- The GT-7017-ELU is designed to determine the characteristics of materials such as plastics, rubber, leather, and fabrics after aging.
- This aging oven helps operators to evaluate the effects of aging on samples, including discoloration, splitting, shrinkage, and extension after exposure to specified temperature for a prescribed period of time.
-
Standards
- GB/T 3512-2014 Type 1
- ISO 188:2011 Type 1
Principle
The aging oven is designed specifically to assess the characteristics of materials, including plastics, rubber, leather, and fabrics after aging. By evaluating the effects on samples such as discoloration, splitting, shrinkage, and extension after exposure to a specified temperature for a prescribed period of time, the stability and reliability of the samples can be determined.
Wide applicability:
Well-suited across diverse industries such as aerospace, material science, footwear, leather, construction, automotive, electronics, medical device, and industrial manufacturing.
Authentic simulation:
Precisely replicates the aging process of materials under high temperature for accurate performance evaluation.
Product service life prediction:
Allows manufacturers to predict the service life of products when subjected to high temperature over a long period of time.
Thermal endurance evaluation:
Ideal for evaluating the thermal endurance of plastic and rubber materials.
Comprehensive performance evaluation:
Enables operators to assess the performance of materials, including discoloration, splitting, shrinkage, and extension.
Precise temperature control:
Equipped with high precision temperature control system to ensure uniform temperature distribution.
Quality assurance:
As a significant instrument in quality assurance, the aging oven helps manufacturers ensure consistency and reliability in product quality.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Air change capability
Ensures consistent and efficient air change within the aging oven using the air circulation tunnel.
LCD control panel
The intuitive and easy to use interface allows operators to quickly learn how to operate the instrument.
Multi-point calibration
Ensures testing accuracy and precision through multi-point calibration.
-
左右滑動看表格
Temp. range Ambient temp.+10℃ to 300℃ Temp. resolution 0.1℃ Temp. accuracy ≦100℃: ±1℃
101 to 200℃: ±2℃
201 to 300℃: ±3℃Turntable speed 5 rpm to 10rpm Air change rate 3 to 10 times/hr Oven air speed 0.5m/s to 1.5m/s Viewing window dimensions 155×185mm (D×H) Test time 0 to 9999H59min (adjustable) Interior dimensions (W×D×H) 50cm×50cm×60cm Exterior dimensions (W×D×H) 90cm×82cm×165cm Power 1∮ AC 220V 50Hz/60Hz (or specify) Output 3.5KW
-
Details
Standards
- GB/T 3512-2014 Type 1
- ISO 188:2011 Type 1
Principle
The aging oven is designed specifically to assess the characteristics of materials, including plastics, rubber, leather, and fabrics after aging. By evaluating the effects on samples such as discoloration, splitting, shrinkage, and extension after exposure to a specified temperature for a prescribed period of time, the stability and reliability of the samples can be determined.
Wide applicability:
Well-suited across diverse industries such as aerospace, material science, footwear, leather, construction, automotive, electronics, medical device, and industrial manufacturing.
Authentic simulation:
Precisely replicates the aging process of materials under high temperature for accurate performance evaluation.
Product service life prediction:
Allows manufacturers to predict the service life of products when subjected to high temperature over a long period of time.
Thermal endurance evaluation:
Ideal for evaluating the thermal endurance of plastic and rubber materials.
Comprehensive performance evaluation:
Enables operators to assess the performance of materials, including discoloration, splitting, shrinkage, and extension.
Precise temperature control:
Equipped with high precision temperature control system to ensure uniform temperature distribution.
Quality assurance:
As a significant instrument in quality assurance, the aging oven helps manufacturers ensure consistency and reliability in product quality.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Features
Air change capability
Ensures consistent and efficient air change within the aging oven using the air circulation tunnel.
LCD control panel
The intuitive and easy to use interface allows operators to quickly learn how to operate the instrument.
Multi-point calibration
Ensures testing accuracy and precision through multi-point calibration.
-
Specifications左右滑動看表格
Temp. range Ambient temp.+10℃ to 300℃ Temp. resolution 0.1℃ Temp. accuracy ≦100℃: ±1℃
101 to 200℃: ±2℃
201 to 300℃: ±3℃Turntable speed 5 rpm to 10rpm Air change rate 3 to 10 times/hr Oven air speed 0.5m/s to 1.5m/s Viewing window dimensions 155×185mm (D×H) Test time 0 to 9999H59min (adjustable) Interior dimensions (W×D×H) 50cm×50cm×60cm Exterior dimensions (W×D×H) 90cm×82cm×165cm Power 1∮ AC 220V 50Hz/60Hz (or specify) Output 3.5KW