- The melt flow indexer measures the extrusion rate of melted thermoplastics through a standard die under a prescribed temperature and load.
- The melt flow rate data can help in optimizing the manufacturing process, maintaining quality control, and selecting the appropriate materials for production in the plastic industry.
-
Referenced standard
- ASTM D1238
- GB/T 3682
- ISO 1133
- JIS K7210
Principle
The melt flow indexer measures the extrusion rate of molten resins through an orifice die under controlled temperature and load. Timed measurements are taken during the test process to ensure accuracy and repeatability. This instrument is particularly effective for evaluating melt flow and manufacturing characteristics, allowing operator to check whether the tested materials meet specific production requirements or not.
Well-suited for diverse industries:
Suitable for various industries such as plastics, materials science, construction, automotive, scientific research, medical devices, electronics, environmental engineering, and industrial manufacturing.
Wide applicability:
Applicable to different types of plastics and polymers.
Quality control:
Helps in maintaining the quality of materials, reducing defects in manufacturing.
Optimizing manufacturing process:
Increasing the production efficiency and reducing manufacturing costs in manufacturing.
Materials selection:
Providing valuable data to enhance materials performance and facilitate materials selection, ensuring they meet specific production requirements.
Research and innovation:
Ensuring new products or materials can meet expected performance.
Standard conformance:
Verify whether the products meet the industrial criteria and regulations.
Environmental protection:
Assists in choosing sustainable and eco-friendly materials.
-
Direct and intuitive control interface
Intuitive and easy to operate control interface for quick operation without extensive learning.
Live data and status display
Enabling operators to monitor and observe test process in real-time via live data and status display.
Wide applicability
Offering great flexibility in setting test conditions such as temperature and load and well-suited for a variety of thermoplastic materials and applications.
-
左右滑動看表格
Temperature control Room temp. ~450 °C(accuracy ± 0.1°C),PID control, include overheat protection. Temp display Imported digital type temperature controller Load 1000g , 1200g , 2160g , 3800g , 5000g , 7160g , 10000g , 12500g , 21600g ,(Optional combination of weights) Folw rate of applicable materials 0.15~50g / 10 min Auto cutoff device Auto / manual selection , time interval 99min59sec Loading Method Manually pressurize Accessories Piston rod Charging rod Cylinder cleaning rod Cylinder brush Die gauge set (go/no go) Die cleaning drill Filling funnel Observation mirror Dimerision (W×D×H) 37 × 51 × 56 cm Weight 42 kg (without weights) Power 1∮,AC220V,50/60Hz,5A (Specified by user)
-
Details
Referenced standard
- ASTM D1238
- GB/T 3682
- ISO 1133
- JIS K7210
Principle
The melt flow indexer measures the extrusion rate of molten resins through an orifice die under controlled temperature and load. Timed measurements are taken during the test process to ensure accuracy and repeatability. This instrument is particularly effective for evaluating melt flow and manufacturing characteristics, allowing operator to check whether the tested materials meet specific production requirements or not.
Well-suited for diverse industries:
Suitable for various industries such as plastics, materials science, construction, automotive, scientific research, medical devices, electronics, environmental engineering, and industrial manufacturing.
Wide applicability:
Applicable to different types of plastics and polymers.
Quality control:
Helps in maintaining the quality of materials, reducing defects in manufacturing.
Optimizing manufacturing process:
Increasing the production efficiency and reducing manufacturing costs in manufacturing.
Materials selection:
Providing valuable data to enhance materials performance and facilitate materials selection, ensuring they meet specific production requirements.
Research and innovation:
Ensuring new products or materials can meet expected performance.
Standard conformance:
Verify whether the products meet the industrial criteria and regulations.
Environmental protection:
Assists in choosing sustainable and eco-friendly materials.
-
Features
Direct and intuitive control interface
Intuitive and easy to operate control interface for quick operation without extensive learning.
Live data and status display
Enabling operators to monitor and observe test process in real-time via live data and status display.
Wide applicability
Offering great flexibility in setting test conditions such as temperature and load and well-suited for a variety of thermoplastic materials and applications.
-
Specifications左右滑動看表格
Temperature control Room temp. ~450 °C(accuracy ± 0.1°C),PID control, include overheat protection. Temp display Imported digital type temperature controller Load 1000g , 1200g , 2160g , 3800g , 5000g , 7160g , 10000g , 12500g , 21600g ,(Optional combination of weights) Folw rate of applicable materials 0.15~50g / 10 min Auto cutoff device Auto / manual selection , time interval 99min59sec Loading Method Manually pressurize Accessories Piston rod Charging rod Cylinder cleaning rod Cylinder brush Die gauge set (go/no go) Die cleaning drill Filling funnel Observation mirror Dimerision (W×D×H) 37 × 51 × 56 cm Weight 42 kg (without weights) Power 1∮,AC220V,50/60Hz,5A (Specified by user)