- The GT-7049-ESU is specifically designed to assess the compressive strength of safety footwear.
- This instrument supports both compressive strength tests for metallic toecaps and penetration tests for shoe soles.
-
Standards
- CAN/CSA-Z195
- GB/T 20991-5.5/5.8
- ISO 20344-2021
- ASTM F2412
Principle
The GT-7049-ESU supports both compressive strength tests for metallic toecaps and penetration tests for shoe soles. To conduct either of these tests, the test specimen is placed between two platens or held by clamping platens and subjected to compression or penetration at a specific pressure or speed.
Wide applicability:
Well-suited to assess both the compression resistance of the metallic toecaps and the penetration resistance of the shoe soles.
Compressive resistance test for toecaps:
This instrument is designed to assess the compressive strength of metallic toecaps in safety footwear, ensuring that the toecap can protect the foot when subjected to external pressure.
Penetration resistance test for soles:
Supports the penetration resistance tests for soles, allowing manufacturers to verify if the sole provides adequate protection.
Safety performance assessment:
Provides valuable insights into the compression and penetration resistance of shoe materials, helping manufacturers evaluate the performance of safety footwear.
Efficient testing procedures:
With its servo-controlled system, this instrument ensures precise control during testing processes and delivers accurate test results.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Multifunctionality
Supports both compressive strength tests for toecaps and penetration tests for soles with appropriate grips.
Reliability
Utilizing high-precision servo control system to precisely conduct testing and ensure test results accuracy.
Flexible test options
The dedicated software and flexible parameters settings allow operators to easily set and modify test conditions to meet a variety of testing requirements.
Real-time monitoring
By monitoring and recording real-time data during test processes, the GT-7049-ESU offers clear insights into the compressive strength of safety footwear.
Powerful database
Enables operators to store, manage, and efficiently search test data, facilitating the analysis of material performance.
Safety features
Equipped with advanced safety devices, including overload protection systems and an emergency stop, ensuring secure operations and protecting both users and equipment.
-
左右滑動看表格
Capacity 5000 kgfLoad resolution 1/500,000 Stroke resolution 0.0025 mm Unit kgf, lbf, N, KN, Kpa, Mpa, mm, cm or inch Load accuracy ±0.5% Test speed 0.01~100 mm/min Speed accuracy ±0.5% Load control speed range 0.005-10%FS/S Load control speed accuracy Load control speed<0.1% F.S/s: ±1% Load control speed > 0.1% F.S/s: ±0.5% Force amplification ratio Rangeless Sampling rate 200 times/sec Amplifier U70 Communication interface RJ45 Driving system Servo motor Power 1∮ AC 220V (or specify)
*Product design and specifications are subject to change without notice.
-
Details
Standards
- CAN/CSA-Z195
- GB/T 20991-5.5/5.8
- ISO 20344-2021
- ASTM F2412
Principle
The GT-7049-ESU supports both compressive strength tests for metallic toecaps and penetration tests for shoe soles. To conduct either of these tests, the test specimen is placed between two platens or held by clamping platens and subjected to compression or penetration at a specific pressure or speed.
Wide applicability:
Well-suited to assess both the compression resistance of the metallic toecaps and the penetration resistance of the shoe soles.
Compressive resistance test for toecaps:
This instrument is designed to assess the compressive strength of metallic toecaps in safety footwear, ensuring that the toecap can protect the foot when subjected to external pressure.
Penetration resistance test for soles:
Supports the penetration resistance tests for soles, allowing manufacturers to verify if the sole provides adequate protection.
Safety performance assessment:
Provides valuable insights into the compression and penetration resistance of shoe materials, helping manufacturers evaluate the performance of safety footwear.
Efficient testing procedures:
With its servo-controlled system, this instrument ensures precise control during testing processes and delivers accurate test results.
Standard conformity:
Ensures that products meet industry standards and satisfy quality expectations in the market.
-
Features
Multifunctionality
Supports both compressive strength tests for toecaps and penetration tests for soles with appropriate grips.
Reliability
Utilizing high-precision servo control system to precisely conduct testing and ensure test results accuracy.
Flexible test options
The dedicated software and flexible parameters settings allow operators to easily set and modify test conditions to meet a variety of testing requirements.
Real-time monitoring
By monitoring and recording real-time data during test processes, the GT-7049-ESU offers clear insights into the compressive strength of safety footwear.
Powerful database
Enables operators to store, manage, and efficiently search test data, facilitating the analysis of material performance.
Safety features
Equipped with advanced safety devices, including overload protection systems and an emergency stop, ensuring secure operations and protecting both users and equipment.
-
Specifications左右滑動看表格
Capacity 5000 kgfLoad resolution 1/500,000 Stroke resolution 0.0025 mm Unit kgf, lbf, N, KN, Kpa, Mpa, mm, cm or inch Load accuracy ±0.5% Test speed 0.01~100 mm/min Speed accuracy ±0.5% Load control speed range 0.005-10%FS/S Load control speed accuracy Load control speed<0.1% F.S/s: ±1% Load control speed > 0.1% F.S/s: ±0.5% Force amplification ratio Rangeless Sampling rate 200 times/sec Amplifier U70 Communication interface RJ45 Driving system Servo motor Power 1∮ AC 220V (or specify)